Post Offer Free
Yuyao Bote Water Purifier Equipment Factory  

Gold Index: 11179

You are here: home  > Reverse Osmosis Parts Portable PH Test Pen With Printed Plastic Housing

Reverse Osmosis Parts Portable PH Test Pen With Printed Plastic Housing 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: PH - 2

Reverse Osmosis Parts Portable PH Test Pen With Printed Plastic Housing
<p style="text-align:cent

Reverse Osmosis Parts Portable PH Test Pen With Printed Plastic Housing

 

Specifications
 
measure range resolution accuracy power supply
0.00-14.00ph 0.01ph +/-0.01ph 2*1.5v
operation temp calibration size weight
0-80C two point automatic calibration 153*29*16cm 52g

 

Attention :

The instrument need recalibrate in the following condition .

1 . Long time no use or use very long time after calibration .

2 . The electrode is used Very frequently .

3 . The testing accuracy requirement is very high .

4 . Press the "CAL" button long time in the air carelessly .

 

PH electrode maintenance :

If the electrode placed long time , and electrode exposed to air ,

then showing values is slow and not stable, because of electrode dry .

You should immerse the electrode into water for few hours .

 

PH meter works :

PH meter is a potential measurement method to measure the PH value of the solution , so PH meter work , in addition to measuring the PH value of the solution , it can also measure the battery's EMF . PH in Latin , is the abbreviation of Pondus hydrogenii , is the activity of hydrogen ions in the material , PH value is the hydrogen ion concentration logarithmic negative .
PH meter's main measurement component glass electrode and reference electrode , glass electrode is sensitive to PH , while the reference electrode potential is stable . The PH meter of these two electrodes together into the same solution , to form a galvanic cell , and the potential of the original battery , is the glass electrode and reference electrode potential algebra .

PH potential of the reference electrode is stable , then the temperature remains stable , the solution and the electrode composed of the original battery potential changes only with the glass electrode potential , and the glass electrode potential depends on the measured solution PH Value , so by measuring the potential changes , we can get PH PH value of the solution .

 

 

PH range 2-12.00PH (8680) , 0.00-14.00 (8681/8682)
Degree of analysis 0.01 PH
Accuracy ± 0.3PH (8680), ± 0.2pH (8681), ± 0.05PH (8682)
MV range -499 to 499
Degree of analysis 0.1 mV (± 0.1 to 195.0) / ± 1 mV (± 190 to 499.0)
Operating temperature 0 to 50 ° C (32 ° C to 122 ° F)
Working humidity 0 to 80% RH
input resistance 1012Ω

 

PH meter structure :

PH meter structure , including composite electrode and galvanometer , composite electrode is what we call the reference electrode and reference electrode , in general , PH indicator electrode are glass electrodes . The function of the glass electrode is sensitive to hydrogen ions in the solution , and the potential difference is reflected by the change of the hydrogen ion . The role of the reference electrode is to provide a constant potential as a deviation from the reference potential .

PH meter components , the galvanometer is used to measure the overall potential , it can be great resistance in the circuit to capture a small potential changes , and the changes shown by the meter out . In order to facilitate reading , PH meter has a display function , that is , the output current meter into PH readings .

 

 

 

 

 

bigPhoto
 Mr. Mr.li

Tel: 86-574-62387776